Coagulant vs flocculant: choosing alum, PAC or polymer for industrial water treatment

“Flocculant” is the word most people type when they have dirty water to clear, whether it’s a dam, a site sediment basin, a process tank or a wash-down pit. But the product that does most of the work is often a coagulant, and picking the wrong one (or the wrong dose) can leave you with water that still won’t settle, or water that settles but now fails on pH.

This guide is for site managers, environmental officers and plant operators choosing a clarifying chemical for industrial and site water. It explains the difference between coagulants and flocculants, compares the common options, and sets out the jar test you should run before you dose anything at scale.

Coagulant vs flocculant: the short answer

  • A coagulant neutralises charge. Most clay and colloidal particles in water carry a negative charge, so they repel each other and stay suspended. A coagulant adds positive ions that cancel that charge, so the particles can start to clump. Aluminium compounds such as aluminium sulphate (alum), polyaluminium chloride (PAC) and aluminium chlorohydrate (ACH) are the most common because trivalent aluminium is far more effective at charge neutralisation than calcium (IECA, 2018).
  • A flocculant binds particles together. Flocculants, usually long-chain polymers, physically bridge particles into larger, heavier flocs that settle faster. They can be natural (starches, gums, chitosan) or synthetic (polyacrylamide, PAM), and anionic, cationic or non-ionic (IECA, 2018).

In practice the two are often used together: a coagulant first to destabilise the particles, then a flocculant to build bigger flocs. Many products sold as “flocculant”, including alum, are technically coagulants.

Why the particles won’t settle on their own

Fine clays are the problem. NSW’s Managing Urban Stormwater: Soils and Construction (the “Blue Book”) classes soils with a significant share of fine, dispersible material as Type D soils, which “will never settle unless flocculated”. Sediment basins on Type D soils require flocculation; basins on fine but non-dispersible Type F soils need longer settling time instead (Landcom, 2004).

The same physics applies to a turbid farm or storage dam, a quarry pond or a process-water tank: if the particles are colloidal clay, gravity alone won’t clear the water in any useful time.

The common options compared

The indicative rates below are from IECA Australasia’s coagulants and flocculants fact sheet (June 2018), written for erosion and sediment control basins. They are starting points for a jar test, not dose recommendations, and your site water will differ.

Agent Type Indicative dose (IECA) Strengths Watch-outs
Gypsum (calcium sulphate) Coagulant 300–600 kg/ML, powder Little pH change, passive use Slow (days rather than hours), poorly soluble, large quantities, raises EC
Calcium chloride Coagulant 250–1,000 kg/ML More soluble than gypsum, little pH change Generally slow, can raise EC a lot
Alum (aluminium sulphate) Coagulant 50–150 kg/ML powder; 100–250 L/ML liquid High solubility, fast acting Lowers pH; needs alkalinity; may need pH buffering after treatment
PAC (polyaluminium chloride) Coagulant 50–200 L/ML Fast, lower dose rates, higher basicity than alum Can still lower pH; needs medium alkalinity
ACH (aluminium chlorohydrate) Coagulant 20–100 L/ML, liquid only Fast, low dose, little pH change Liquid only
Bio-polymers (chitosan, gums, starches) Flocculant Product dependent Fast, large stable flocs, biodegradable May need a coagulant first
PAM (polyacrylamide) Flocculant Product dependent Works in active and passive systems Cationic forms carry a higher ecotoxicity risk

Alum, PAC and pH

The biggest practical difference between the aluminium coagulants is what they do to pH. When alum reacts in water it forms six hydrogen ions, PAC three and ACH one, so alum tends to drop pH the most (IECA, 2018). If your water has little natural alkalinity, an alkalinity increaser such as hydrated lime or caustic soda may be needed to keep coagulation working and to bring pH back before discharge.

For drinking-water treatment, the Australian Drinking Water Guidelines put alum’s optimum coagulation range at about pH 5.5 to 7.5, with the lower end used for removing organics and the upper end for sweep coagulation (NHMRC, ADWG treatment chemical fact sheet). That’s a useful reference point for process water too: dose and pH have to be set together.

Don’t overdose

More coagulant isn’t better. Overdosing a cationic coagulant can reverse the particles’ charge so they repel each other again and stop settling (IECA, 2018). In drinking water, excess aluminium can also form a milky floc after treatment. The ADWG sets an aesthetic guideline of 0.2 mg/L acid-soluble aluminium in drinking water, preferably below 0.1 mg/L, and no health-based guideline (NHMRC, ADWG aluminium fact sheet).

Think about the receiving water

If treated water leaves your site, ecotoxicity matters. IECA notes that dissolved aluminium at 0.05 to 0.1 mg/L and pH 6.5 to 8.0 presents little threat of toxicity, but toxicity increases at lower pH, and that cationic polymers carry greater toxicity risk to fish than anionic or non-ionic polymers (IECA, 2018). Ask your supplier for the product’s ecotoxicity data, and check the discharge conditions in your own approval.

Jar test before you dose

IECA’s position is blunt: the most efficient coagulant or flocculant, and its dose, can only be found by jar testing (IECA, 2018). A basic jar test looks like this:

  1. Collect representative water. Use raw water from site at the temperature you expect in the basin or tank. If you don’t have runoff yet, IECA describes mixing about 100 g of sieved site soil into 10 L of water.
  2. Fill matched 1 L beakers and record starting pH, temperature and turbidity. Keep one beaker untreated as a control.
  3. Dose each beaker differently, either different products or the same product at a range of doses.
  4. Mix the way IECA describes: a slow stir (40–50 rpm) for 30 seconds, dose, a rapid stir (100–125 rpm) for 15–30 seconds, then a slow stir (40 rpm) for up to 5 minutes.
  5. Let it settle, then record clarity, turbidity and pH for each beaker.
  6. Pick with a safety margin. For sediment basins, IECA recommends only selecting a product that reaches at least 100 mm of clarity within 15 minutes, because real basins settle more slowly than a beaker.

Scale the winning dose to your volume (for example, kg or L per megalitre) and confirm the result on site with a turbidity or TSS sample before discharge.

Matching the product to the job

  • Construction and quarry sediment basins: follow your erosion and sediment control plan and approval. Liquid alum, PAC or ACH are common for batch treatment; gypsum suits passive, slow treatment where pH change must be minimal (IECA, 2018).
  • Turbid dams and storages: jar test first, check alkalinity, and plan for pH correction if you use alum.
  • Process water and pre-treatment: a coagulant ahead of a filter can help capture fine colloids. Dose and pH need to be set together, and residual aluminium should be checked if the water is used downstream.
  • Wastewater and wash-down: coagulants can help settle solids before discharge to sewer, but your trade waste approval sets the limits that matter.

What Viva Blu supplies

Viva Blu supplies coagulants for industrial and site use from Windsor, Brisbane, including liquid aluminium sulphate (20 L), granular aluminium sulphate (25 kg), PAC 10% and our Coagulant 20 L. See the full coagulants and flocculants range, plus caustic soda pearls for pH correction. Always read the SDS before handling.

Buying for a site or a regular program? Register for a B2B account or contact us at contact@vivablu.com.au or 0402 981 808 to talk through volumes and supply.

Frequently asked questions

Is alum a coagulant or a flocculant?
Alum (aluminium sulphate) is a coagulant: it neutralises particle charge. It is often sold as a “flocculant” because the end result is floc that settles.

Which is better, alum or PAC?
It depends on your water. PAC usually works at lower doses and drops pH less than alum, while alum is widely used and well understood. Jar test both.

Do I need a flocculant as well as a coagulant?
Not always. A coagulant alone can clear many waters. A polymer flocculant helps when flocs are small or settle slowly, but choose the polymer type carefully if water is discharged.

How much coagulant do I need?
Only a jar test on your water can tell you. Published ranges, such as IECA’s, are starting points.

Will alum lower my pH?
Usually, yes. Check alkalinity before dosing and pH after, and correct it before discharge if needed.